mirror of
				https://github.com/python/cpython.git
				synced 2025-10-31 05:31:20 +00:00 
			
		
		
		
	
		
			
				
	
	
		
			490 lines
		
	
	
	
		
			21 KiB
		
	
	
	
		
			TeX
		
	
	
	
	
	
			
		
		
	
	
			490 lines
		
	
	
	
		
			21 KiB
		
	
	
	
		
			TeX
		
	
	
	
	
	
| \section{\module{sys} ---
 | |
|          System-specific parameters and functions}
 | |
| 
 | |
| \declaremodule{builtin}{sys}
 | |
| \modulesynopsis{Access system-specific parameters and functions.}
 | |
| 
 | |
| This module provides access to some variables used or maintained by the
 | |
| interpreter and to functions that interact strongly with the interpreter.
 | |
| It is always available.
 | |
| 
 | |
| 
 | |
| \begin{datadesc}{argv}
 | |
|   The list of command line arguments passed to a Python script.
 | |
|   \code{argv[0]} is the script name (it is operating system dependent
 | |
|   whether this is a full pathname or not).  If the command was
 | |
|   executed using the \programopt{-c} command line option to the
 | |
|   interpreter, \code{argv[0]} is set to the string \code{'-c'}.  If no
 | |
|   script name was passed to the Python interpreter, \code{argv} has
 | |
|   zero length.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{byteorder}
 | |
|   An indicator of the native byte order.  This will have the value
 | |
|   \code{'big'} on big-endian (most-signigicant byte first) platforms,
 | |
|   and \code{'little'} on little-endian (least-significant byte first)
 | |
|   platforms.
 | |
|   \versionadded{2.0}
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{builtin_module_names}
 | |
|   A tuple of strings giving the names of all modules that are compiled
 | |
|   into this Python interpreter.  (This information is not available in
 | |
|   any other way --- \code{modules.keys()} only lists the imported
 | |
|   modules.)
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{copyright}
 | |
|   A string containing the copyright pertaining to the Python
 | |
|   interpreter.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{dllhandle}
 | |
|   Integer specifying the handle of the Python DLL.
 | |
|   Availability: Windows.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{funcdesc}{displayhook}{\var{value}}
 | |
|   If \var{value} is not \code{None}, this function prints it to
 | |
|   \code{sys.stdout}, and saves it in \code{__builtin__._}.
 | |
| 
 | |
|   \code{sys.displayhook} is called on the result of evaluating an
 | |
|   expression entered in an interactive Python session.  The display of
 | |
|   these values can be customized by assigning another one-argument
 | |
|   function to \code{sys.displayhook}.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{excepthook}{\var{type}, \var{value}, \var{traceback}}
 | |
|   This function prints out a given traceback and exception to
 | |
|   \code{sys.stderr}.
 | |
| 
 | |
|   When an exception is raised and uncaught, the interpreter calls
 | |
|   \code{sys.excepthook} with three arguments, the exception class,
 | |
|   exception instance, and a traceback object.  In an interactive
 | |
|   session this happens just before control is returned to the prompt;
 | |
|   in a Python program this happens just before the program exits.  The
 | |
|   handling of such top-level exceptions can be customized by assigning
 | |
|   another three-argument function to \code{sys.excepthook}.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{datadesc}{__displayhook__}
 | |
| \dataline{__excepthook__}
 | |
|   These objects contain the original values of \code{displayhook} and
 | |
|   \code{excepthook} at the start of the program.  They are saved so
 | |
|   that \code{displayhook} and \code{excepthook} can be restored in
 | |
|   case they happen to get replaced with broken objects.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{funcdesc}{exc_info}{}
 | |
|   This function returns a tuple of three values that give information
 | |
|   about the exception that is currently being handled.  The
 | |
|   information returned is specific both to the current thread and to
 | |
|   the current stack frame.  If the current stack frame is not handling
 | |
|   an exception, the information is taken from the calling stack frame,
 | |
|   or its caller, and so on until a stack frame is found that is
 | |
|   handling an exception.  Here, ``handling an exception'' is defined
 | |
|   as ``executing or having executed an except clause.''  For any stack
 | |
|   frame, only information about the most recently handled exception is
 | |
|   accessible.
 | |
| 
 | |
|   If no exception is being handled anywhere on the stack, a tuple
 | |
|   containing three \code{None} values is returned.  Otherwise, the
 | |
|   values returned are \code{(\var{type}, \var{value},
 | |
|   \var{traceback})}.  Their meaning is: \var{type} gets the exception
 | |
|   type of the exception being handled (a string or class object);
 | |
|   \var{value} gets the exception parameter (its \dfn{associated value}
 | |
|   or the second argument to \keyword{raise}, which is always a class
 | |
|   instance if the exception type is a class object); \var{traceback}
 | |
|   gets a traceback object (see the Reference Manual) which
 | |
|   encapsulates the call stack at the point where the exception
 | |
|   originally occurred.  \obindex{traceback}
 | |
| 
 | |
|   \warning{Assigning the \var{traceback} return value to a
 | |
|   local variable in a function that is handling an exception will
 | |
|   cause a circular reference.  This will prevent anything referenced
 | |
|   by a local variable in the same function or by the traceback from
 | |
|   being garbage collected.  Since most functions don't need access to
 | |
|   the traceback, the best solution is to use something like
 | |
|   \code{exctype, value = sys.exc_info()[:2]} to extract only the
 | |
|   exception type and value.  If you do need the traceback, make sure
 | |
|   to delete it after use (best done with a \keyword{try}
 | |
|   ... \keyword{finally} statement) or to call \function{exc_info()} in
 | |
|   a function that does not itself handle an exception.} \note{Beginning
 | |
|   with Python 2.2, such cycles are automatically reclaimed when garbage
 | |
|   collection is enabled and they become unreachable, but it remains more
 | |
|   efficient to avoid creating cycles.}
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{datadesc}{exc_type}
 | |
| \dataline{exc_value}
 | |
| \dataline{exc_traceback}
 | |
| \deprecated {1.5}
 | |
|             {Use \function{exc_info()} instead.}
 | |
|   Since they are global variables, they are not specific to the
 | |
|   current thread, so their use is not safe in a multi-threaded
 | |
|   program.  When no exception is being handled, \code{exc_type} is set
 | |
|   to \code{None} and the other two are undefined.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{exec_prefix}
 | |
|   A string giving the site-specific directory prefix where the
 | |
|   platform-dependent Python files are installed; by default, this is
 | |
|   also \code{'/usr/local'}.  This can be set at build time with the
 | |
|   \longprogramopt{exec-prefix} argument to the \program{configure}
 | |
|   script.  Specifically, all configuration files (e.g. the
 | |
|   \file{pyconfig.h} header file) are installed in the directory
 | |
|   \code{exec_prefix + '/lib/python\var{version}/config'}, and shared
 | |
|   library modules are installed in \code{exec_prefix +
 | |
|   '/lib/python\var{version}/lib-dynload'}, where \var{version} is
 | |
|   equal to \code{version[:3]}.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{executable}
 | |
|   A string giving the name of the executable binary for the Python
 | |
|   interpreter, on systems where this makes sense.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{funcdesc}{exit}{\optional{arg}}
 | |
|   Exit from Python.  This is implemented by raising the
 | |
|   \exception{SystemExit} exception, so cleanup actions specified by
 | |
|   finally clauses of \keyword{try} statements are honored, and it is
 | |
|   possible to intercept the exit attempt at an outer level.  The
 | |
|   optional argument \var{arg} can be an integer giving the exit status
 | |
|   (defaulting to zero), or another type of object.  If it is an
 | |
|   integer, zero is considered ``successful termination'' and any
 | |
|   nonzero value is considered ``abnormal termination'' by shells and
 | |
|   the like.  Most systems require it to be in the range 0-127, and
 | |
|   produce undefined results otherwise.  Some systems have a convention
 | |
|   for assigning specific meanings to specific exit codes, but these
 | |
|   are generally underdeveloped; \UNIX{} programs generally use 2 for
 | |
|   command line syntax errors and 1 for all other kind of errors.  If
 | |
|   another type of object is passed, \code{None} is equivalent to
 | |
|   passing zero, and any other object is printed to \code{sys.stderr}
 | |
|   and results in an exit code of 1.  In particular,
 | |
|   \code{sys.exit("some error message")} is a quick way to exit a
 | |
|   program when an error occurs.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{datadesc}{exitfunc}
 | |
|   This value is not actually defined by the module, but can be set by
 | |
|   the user (or by a program) to specify a clean-up action at program
 | |
|   exit.  When set, it should be a parameterless function.  This
 | |
|   function will be called when the interpreter exits.  Only one
 | |
|   function may be installed in this way; to allow multiple functions
 | |
|   which will be called at termination, use the \refmodule{atexit}
 | |
|   module.  \note{The exit function is not called when the program is
 | |
|   killed by a signal, when a Python fatal internal error is detected,
 | |
|   or when \code{os._exit()} is called.}
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{funcdesc}{getdefaultencoding}{}
 | |
|   Return the name of the current default string encoding used by the
 | |
|   Unicode implementation.
 | |
|   \versionadded{2.0}
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{getdlopenflags}{}
 | |
|   Return the current value of the flags that are used for
 | |
|   \cfunction{dlopen()} calls. The flag constants are defined in the
 | |
|   \refmodule{dl} and \module{DLFCN} modules.
 | |
|   Availability: \UNIX.
 | |
|   \versionadded{2.2}
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{getrefcount}{object}
 | |
|   Return the reference count of the \var{object}.  The count returned
 | |
|   is generally one higher than you might expect, because it includes
 | |
|   the (temporary) reference as an argument to
 | |
|   \function{getrefcount()}.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{getrecursionlimit}{}
 | |
|   Return the current value of the recursion limit, the maximum depth
 | |
|   of the Python interpreter stack.  This limit prevents infinite
 | |
|   recursion from causing an overflow of the C stack and crashing
 | |
|   Python.  It can be set by \function{setrecursionlimit()}.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{_getframe}{\optional{depth}}
 | |
|   Return a frame object from the call stack.  If optional integer
 | |
|   \var{depth} is given, return the frame object that many calls below
 | |
|   the top of the stack.  If that is deeper than the call stack,
 | |
|   \exception{ValueError} is raised.  The default for \var{depth} is
 | |
|   zero, returning the frame at the top of the call stack.
 | |
| 
 | |
|   This function should be used for internal and specialized purposes
 | |
|   only.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{datadesc}{hexversion}
 | |
|   The version number encoded as a single integer.  This is guaranteed
 | |
|   to increase with each version, including proper support for
 | |
|   non-production releases.  For example, to test that the Python
 | |
|   interpreter is at least version 1.5.2, use:
 | |
| 
 | |
| \begin{verbatim}
 | |
| if sys.hexversion >= 0x010502F0:
 | |
|     # use some advanced feature
 | |
|     ...
 | |
| else:
 | |
|     # use an alternative implementation or warn the user
 | |
|     ...
 | |
| \end{verbatim}
 | |
| 
 | |
|   This is called \samp{hexversion} since it only really looks
 | |
|   meaningful when viewed as the result of passing it to the built-in
 | |
|   \function{hex()} function.  The \code{version_info} value may be
 | |
|   used for a more human-friendly encoding of the same information.
 | |
|   \versionadded{1.5.2}
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{last_type}
 | |
| \dataline{last_value}
 | |
| \dataline{last_traceback}
 | |
|   These three variables are not always defined; they are set when an
 | |
|   exception is not handled and the interpreter prints an error message
 | |
|   and a stack traceback.  Their intended use is to allow an
 | |
|   interactive user to import a debugger module and engage in
 | |
|   post-mortem debugging without having to re-execute the command that
 | |
|   caused the error.  (Typical use is \samp{import pdb; pdb.pm()} to
 | |
|   enter the post-mortem debugger; see chapter \ref{debugger}, ``The
 | |
|   Python Debugger,'' for more information.)
 | |
| 
 | |
|   The meaning of the variables is the same as that of the return
 | |
|   values from \function{exc_info()} above.  (Since there is only one
 | |
|   interactive thread, thread-safety is not a concern for these
 | |
|   variables, unlike for \code{exc_type} etc.)
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{maxint}
 | |
|   The largest positive integer supported by Python's regular integer
 | |
|   type.  This is at least 2**31-1.  The largest negative integer is
 | |
|   \code{-maxint-1} --- the asymmetry results from the use of 2's
 | |
|   complement binary arithmetic.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{maxunicode}
 | |
|   An integer giving the largest supported code point for a Unicode
 | |
|   character.  The value of this depends on the configuration option
 | |
|   that specifies whether Unicode characters are stored as UCS-2 or
 | |
|   UCS-4.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{modules}
 | |
|   This is a dictionary that maps module names to modules which have
 | |
|   already been loaded.  This can be manipulated to force reloading of
 | |
|   modules and other tricks.  Note that removing a module from this
 | |
|   dictionary is \emph{not} the same as calling
 | |
|   \function{reload()}\bifuncindex{reload} on the corresponding module
 | |
|   object.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{path}
 | |
| \indexiii{module}{search}{path}
 | |
|   A list of strings that specifies the search path for modules.
 | |
|   Initialized from the environment variable \envvar{PYTHONPATH}, or an
 | |
|   installation-dependent default.
 | |
| 
 | |
|   The first item of this list, \code{path[0]}, is the directory
 | |
|   containing the script that was used to invoke the Python
 | |
|   interpreter.  If the script directory is not available (e.g.  if the
 | |
|   interpreter is invoked interactively or if the script is read from
 | |
|   standard input), \code{path[0]} is the empty string, which directs
 | |
|   Python to search modules in the current directory first.  Notice
 | |
|   that the script directory is inserted \emph{before} the entries
 | |
|   inserted as a result of \envvar{PYTHONPATH}.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{platform}
 | |
|   This string contains a platform identifier, e.g. \code{'sunos5'} or
 | |
|   \code{'linux1'}.  This can be used to append platform-specific
 | |
|   components to \code{path}, for instance.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{prefix}
 | |
|   A string giving the site-specific directory prefix where the
 | |
|   platform independent Python files are installed; by default, this is
 | |
|   the string \code{'/usr/local'}.  This can be set at build time with
 | |
|   the \longprogramopt{prefix} argument to the \program{configure}
 | |
|   script.  The main collection of Python library modules is installed
 | |
|   in the directory \code{prefix + '/lib/python\var{version}'} while
 | |
|   the platform independent header files (all except \file{pyconfig.h})
 | |
|   are stored in \code{prefix + '/include/python\var{version}'}, where
 | |
|   \var{version} is equal to \code{version[:3]}.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{ps1}
 | |
| \dataline{ps2}
 | |
| \index{interpreter prompts}
 | |
| \index{prompts, interpreter}
 | |
|   Strings specifying the primary and secondary prompt of the
 | |
|   interpreter.  These are only defined if the interpreter is in
 | |
|   interactive mode.  Their initial values in this case are
 | |
|   \code{'>\code{>}> '} and \code{'... '}.  If a non-string object is
 | |
|   assigned to either variable, its \function{str()} is re-evaluated
 | |
|   each time the interpreter prepares to read a new interactive
 | |
|   command; this can be used to implement a dynamic prompt.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{funcdesc}{setcheckinterval}{interval}
 | |
|   Set the interpreter's ``check interval''.  This integer value
 | |
|   determines how often the interpreter checks for periodic things such
 | |
|   as thread switches and signal handlers.  The default is \code{10},
 | |
|   meaning the check is performed every 10 Python virtual instructions.
 | |
|   Setting it to a larger value may increase performance for programs
 | |
|   using threads.  Setting it to a value \code{<=} 0 checks every
 | |
|   virtual instruction, maximizing responsiveness as well as overhead.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{setdefaultencoding}{name}
 | |
|   Set the current default string encoding used by the Unicode
 | |
|   implementation.  If \var{name} does not match any available
 | |
|   encoding, \exception{LookupError} is raised.  This function is only
 | |
|   intended to be used by the \refmodule{site} module implementation
 | |
|   and, where needed, by \module{sitecustomize}.  Once used by the
 | |
|   \refmodule{site} module, it is removed from the \module{sys}
 | |
|   module's namespace.
 | |
| %  Note that \refmodule{site} is not imported if
 | |
| %  the \programopt{-S} option is passed to the interpreter, in which
 | |
| %  case this function will remain available.
 | |
|   \versionadded{2.0}
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{setdlopenflags}{n}
 | |
|   Set the flags used by the interpreter for \cfunction{dlopen()}
 | |
|   calls, such as when the interpreter loads extension modules.  Among
 | |
|   other things, this will enable a lazy resolving of symbols when
 | |
|   importing a module, if called as \code{sys.setdlopenflags(0)}.  To
 | |
|   share symbols across extension modules, call as
 | |
|   \code{sys.setdlopenflags(dl.RTLD_NOW | dl.RTLD_GLOBAL)}.  Symbolic
 | |
|   names for the flag modules can be either found in the \refmodule{dl}
 | |
|   module, or in the \module{DLFCN} module. If \module{DLFCN} is not
 | |
|   available, it can be generated from \file{/usr/include/dlfcn.h}
 | |
|   using the \program{h2py} script.
 | |
|   Availability: \UNIX.
 | |
|   \versionadded{2.2}
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{setprofile}{profilefunc}
 | |
|   Set the system's profile function,\index{profile function} which
 | |
|   allows you to implement a Python source code profiler in
 | |
|   Python.\index{profiler}  See chapter \ref{profile} for more
 | |
|   information on the Python profiler.  The system's profile function
 | |
|   is called similarly to the system's trace function (see
 | |
|   \function{settrace()}), but it isn't called for each executed line
 | |
|   of code (only on call and return, but the return event is reported
 | |
|   even when an exception has been set).  The function is
 | |
|   thread-specific, but there is no way for the profiler to know about
 | |
|   context switches between threads, so it does not make sense to use
 | |
|   this in the presence of multiple threads.
 | |
|   Also, its return value is not used, so it can simply return
 | |
|   \code{None}.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{setrecursionlimit}{limit}
 | |
|   Set the maximum depth of the Python interpreter stack to
 | |
|   \var{limit}.  This limit prevents infinite recursion from causing an
 | |
|   overflow of the C stack and crashing Python.
 | |
| 
 | |
|   The highest possible limit is platform-dependent.  A user may need
 | |
|   to set the limit higher when she has a program that requires deep
 | |
|   recursion and a platform that supports a higher limit.  This should
 | |
|   be done with care, because a too-high limit can lead to a crash.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{funcdesc}{settrace}{tracefunc}
 | |
|   Set the system's trace function,\index{trace function} which allows
 | |
|   you to implement a Python source code debugger in Python.  See
 | |
|   section \ref{debugger-hooks}, ``How It Works,'' in the chapter on
 | |
|   the Python debugger.\index{debugger}  The function is
 | |
|   thread-specific; for a debugger to support multiple threads, it must
 | |
|   be registered using \function{settrace()} for each thread being
 | |
|   debugged.
 | |
| \end{funcdesc}
 | |
| 
 | |
| \begin{datadesc}{stdin}
 | |
| \dataline{stdout}
 | |
| \dataline{stderr}
 | |
|   File objects corresponding to the interpreter's standard input,
 | |
|   output and error streams.  \code{stdin} is used for all interpreter
 | |
|   input except for scripts but including calls to
 | |
|   \function{input()}\bifuncindex{input} and
 | |
|   \function{raw_input()}\bifuncindex{raw_input}.  \code{stdout} is
 | |
|   used for the output of \keyword{print} and expression statements and
 | |
|   for the prompts of \function{input()} and \function{raw_input()}.
 | |
|   The interpreter's own prompts and (almost all of) its error messages
 | |
|   go to \code{stderr}.  \code{stdout} and \code{stderr} needn't be
 | |
|   built-in file objects: any object is acceptable as long as it has a
 | |
|   \method{write()} method that takes a string argument.  (Changing
 | |
|   these objects doesn't affect the standard I/O streams of processes
 | |
|   executed by \function{os.popen()}, \function{os.system()} or the
 | |
|   \function{exec*()} family of functions in the \refmodule{os}
 | |
|   module.)
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{__stdin__}
 | |
| \dataline{__stdout__}
 | |
| \dataline{__stderr__}
 | |
|   These objects contain the original values of \code{stdin},
 | |
|   \code{stderr} and \code{stdout} at the start of the program.  They
 | |
|   are used during finalization, and could be useful to restore the
 | |
|   actual files to known working file objects in case they have been
 | |
|   overwritten with a broken object.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{tracebacklimit}
 | |
|   When this variable is set to an integer value, it determines the
 | |
|   maximum number of levels of traceback information printed when an
 | |
|   unhandled exception occurs.  The default is \code{1000}.  When set
 | |
|   to \code{0} or less, all traceback information is suppressed and
 | |
|   only the exception type and value are printed.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{version}
 | |
|   A string containing the version number of the Python interpreter
 | |
|   plus additional information on the build number and compiler used.
 | |
|   It has a value of the form \code{'\var{version}
 | |
|   (\#\var{build_number}, \var{build_date}, \var{build_time})
 | |
|   [\var{compiler}]'}.  The first three characters are used to identify
 | |
|   the version in the installation directories (where appropriate on
 | |
|   each platform).  An example:
 | |
| 
 | |
| \begin{verbatim}
 | |
| >>> import sys
 | |
| >>> sys.version
 | |
| '1.5.2 (#0 Apr 13 1999, 10:51:12) [MSC 32 bit (Intel)]'
 | |
| \end{verbatim}
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{version_info}
 | |
|   A tuple containing the five components of the version number:
 | |
|   \var{major}, \var{minor}, \var{micro}, \var{releaselevel}, and
 | |
|   \var{serial}.  All values except \var{releaselevel} are integers;
 | |
|   the release level is \code{'alpha'}, \code{'beta'},
 | |
|   \code{'candidate'}, or \code{'final'}.  The \code{version_info}
 | |
|   value corresponding to the Python version 2.0 is \code{(2, 0, 0,
 | |
|   'final', 0)}.
 | |
|   \versionadded{2.0}
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{warnoptions}
 | |
|   This is an implementation detail of the warnings framework; do not
 | |
|   modify this value.  Refer to the \refmodule{warnings} module for
 | |
|   more information on the warnings framework.
 | |
| \end{datadesc}
 | |
| 
 | |
| \begin{datadesc}{winver}
 | |
|   The version number used to form registry keys on Windows platforms.
 | |
|   This is stored as string resource 1000 in the Python DLL.  The value
 | |
|   is normally the first three characters of \constant{version}.  It is
 | |
|   provided in the \module{sys} module for informational purposes;
 | |
|   modifying this value has no effect on the registry keys used by
 | |
|   Python.
 | |
|   Availability: Windows.
 | |
| \end{datadesc}
 | |
| 
 | |
| 
 | |
| \begin{seealso}
 | |
|   \seemodule{site}
 | |
|     {This describes how to use .pth files to extend \code{sys.path}.}
 | |
| \end{seealso}
 | 
