That which cannot happen has not happened.
No immediate changes to Addr or Prog size.
Change-Id: I4cb9315f2c9f5f92eda340bfc4abb46395fa467f
Reviewed-on: https://go-review.googlesource.com/10513
Reviewed-by: Dave Cheney <dave@cheney.net>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Printed and Width were unused.
Despite only removing two bytes, due to alignment, 8 bytes are saved
on 64-bit:
Before: unsafe.Sizeof(obj.Prog{}) == 304
After: unsafe.Sizeof(obj.Prog{}) == 296
The next size class below 320 (304=>19(320)) is 288. Still 8 bytes
away from that.
Change-Id: I8d1632dd40d387f7036c03c65ea4d64e9b6218c3
Reviewed-on: https://go-review.googlesource.com/10511
Run-TryBot: Brad Fitzpatrick <bradfitz@golang.org>
Reviewed-by: Josh Bleecher Snyder <josharian@gmail.com>
It is almost never set and Addr is large, so having the full struct
in the Prog wastes memory most of the time.
Before (on a 64-bit system):
$ sizeof -p cmd/internal/obj Addr Prog
Addr 80
Prog 376
$
After:
$ sizeof -p cmd/internal/obj Addr Prog
Addr 80
Prog 304
$
Change-Id: I491f201241f87543964a7d0f48b85830759be9d0
Reviewed-on: https://go-review.googlesource.com/10457
Reviewed-by: Josh Bleecher Snyder <josharian@gmail.com>
It shrinks Prog type from 448 bytes down to 376 bytes on amd64.
It also makes sense, because I don't know of any modern architecture
that have instructions which can write to two destinations, none of
which is a register (even x86 doesn't have such instructions).
Change-Id: I3061f1c9ac93d79ee2b92ecb9049641d0e0f6300
Reviewed-on: https://go-review.googlesource.com/10330
Reviewed-by: Aram Hăvărneanu <aram@mgk.ro>
Reviewed-by: Josh Bleecher Snyder <josharian@gmail.com>
Reviewed-by: Russ Cox <rsc@golang.org>
F3t was effectively a local variable.
Remove it.
This shrinks obj.Prog from 456 to 448 bytes,
which places it in a smaller malloc class.
This reduces the memory usage of the compiler
while compiling the rotate tests by ~2.75%.
Change-Id: I31cc9dd67269851a430b56bcc7d255c9349eb522
Reviewed-on: https://go-review.googlesource.com/10255
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
This started out as trying to remove Bool2int calls, which it does a bit, but
mostly it ended up being removing the Link.Symmorestack array which seemed a
pointless bit of caching.
Change-Id: I91a51eb08cb4b08f3f9f093b575306499267b67a
Reviewed-on: https://go-review.googlesource.com/9239
Reviewed-by: Minux Ma <minux@golang.org>
Run-TryBot: Minux Ma <minux@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
The long comment block in obj6.go:progedit talked about the two code sequences
for accessing g as "local exec" and "initial exec", but really they are both forms
of local exec. This stuff is confusing enough without using the wrong words for
things, so rewrite it to talk about 2-instruction and 1-instruction sequences.
Unfortunately the confusion has made it into code, with the R_TLS_IE relocation
now doing double duty as meaning actual initial exec when externally linking and
boring old local exec when linking internally (half of this is my fault). So this
stops using R_TLS_IE in the local exec case. There is a chance this might break
plan9 or windows, but I don't think so. Next step is working out what the heck is
going on on ARM...
Change-Id: I09da4388210cf49dbc99fd25f5172bbe517cee57
Reviewed-on: https://go-review.googlesource.com/9273
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Run-TryBot: Ian Lance Taylor <iant@golang.org>
This lets us avoid loading string constants via the GOT and (together with
http://golang.org/cl/9102) results in the fannkuch benchmark having very similar
register usage with -dynlink as without.
Change-Id: Ic3892b399074982b76773c3e547cfbba5dabb6f9
Reviewed-on: https://go-review.googlesource.com/9103
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Run-TryBot: Ian Lance Taylor <iant@golang.org>
They don't really make any sense on this side of the compiler/linker divide.
Some of the code touching these fields was the support for R_TLS when
thechar=='6' which turns out to be dead and so I just removed all of that.
Change-Id: I4e265613c4e7fcc30a965fffb7fd5f45017f06f3
Reviewed-on: https://go-review.googlesource.com/9107
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
http://golang.org/cl/7623 refactored how line history works and
introduced a new TrimPathPrefix field to replace the existing Trimpath
field, but never removed the latter or updated its users.
Fixes#10503.
Change-Id: Ief90a55b6cef2e8062b59856a4c7dcc0df01d3f2
Reviewed-on: https://go-review.googlesource.com/9113
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Run-TryBot: Matthew Dempsky <mdempsky@google.com>
This CL introduces R_ADDRARM64, which is similar to R_ADDRPOWER.
Fixes#10112.
Change-Id: I309e3df7608b9eef9339196fdc50dedf5f9439f1
Reviewed-on: https://go-review.googlesource.com/8438
Reviewed-by: Aram Hăvărneanu <aram@mgk.ro>
Reviewed-by: David Crawshaw <crawshaw@golang.org>
A quick pass through link.go, mostly removing fields that are not
used on the "creating a single object file" side of the fence.
Change-Id: I35ba41378c2c418f7df2f2f88dce65bc64a1a45d
Reviewed-on: https://go-review.googlesource.com/7672
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
The ProgInfo is loaded many times during each analysis pass.
Load it once at the beginning (in Flowstart if using that, or explicitly,
as in plive.go) and then refer to the cached copy.
Removes many calls to proginfo.
Makes Prog a little bigger, but the previous CL more than compensates.
Change-Id: If90a12fc6729878fdae10444f9c3bedc8d85026e
Reviewed-on: https://go-review.googlesource.com/7745
Reviewed-by: Josh Bleecher Snyder <josharian@gmail.com>
An interface{} is more in the spirit of the original union.
By my calculations, on 64-bit systems this reduces
Addr from 120 to 80 bytes, and Prog from 592 to 424 bytes.
Change-Id: I0d7b0981513c2a3c94c9ac76bb4f8816485b5a3c
Reviewed-on: https://go-review.googlesource.com/7744
Reviewed-by: Rob Pike <r@golang.org>
I think the file ended up in the order of the typedefs instead of the
order of the actual struct definitions. You can see where some of
the declarations were because some of the comments didn't move.
Put things back in the original order.
Change-Id: I0e3703008278b084b632c917cfb73bc81bdd4f23
Reviewed-on: https://go-review.googlesource.com/7743
Reviewed-by: Josh Bleecher Snyder <josharian@gmail.com>
In addition to possibly being clearer code,
this replaces an O(n) lookup with an O(log n) lookup.
Change-Id: I0a574c536a965a87f7ad6dcdcc30f737bc771cd5
Reviewed-on: https://go-review.googlesource.com/7623
Reviewed-by: Rob Pike <r@golang.org>
ARM64 (ARMv8) has 32 general purpose, 64-bit integer registers
(R0-R31), 32 64-bit scalar floating point registers (F0-F31), and
32 128-bit vector registers (unused, V0-V31).
R31 is either the stack pointer (RSP), or the zero register (ZR),
depending on the instruction. Note the distinction between the
hardware stack pointer, RSP, and the virtual stack pointer SP.
The (hardware) stack pointer must be 16-byte aligned at all times;
the RSP register itself must be aligned, offset(RSP) only has to
have natural alignment.
Instructions are fixed-width, and are 32-bit wide. ARM64 supports
ARMv7 too (32-bit ARM), but not in the same process. In general,
there is not much in common between 32-bit ARM and ARM64, it's a
new architecture.
All implementations have floating point instructions.
This change adds a Prog.To3 field analogous to Prog.To. It is used
by exclusive load/store instructions such as STLXR which read from
one register, and write to both a register and a memory address.
STLXRW R1, (R0), R3
This will store the word contained in R1 to the memory address
pointed by R0. R3 will be updated with the status result of the
store. It is used to implement atomic operations.
No other changes are made to the portable Prog and Addr structures.
Change-Id: Ie839029aa5265bbad35769d9689eca11e1c48c47
Reviewed-on: https://go-review.googlesource.com/7046
Reviewed-by: Russ Cox <rsc@golang.org>
Just little bits and pieces I noticed were unused in passing, and
some more found with https://github.com/opennota/check.
Change-Id: I199fecdbf8dc2ff9076cf4ea81395275c7f171c3
Reviewed-on: https://go-review.googlesource.com/7033
Reviewed-by: Minux Ma <minux@golang.org>
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
This was inserted by c2go to turn each enum { ... } into one const ( ... ) block,
but it is fragile and was never intended as a long-term thing.
Change-Id: I8de8e0984b130456da70e4d59891276dfef7ac27
Reviewed-on: https://go-review.googlesource.com/6932
Reviewed-by: Rob Pike <r@golang.org>
Remove the per-achitecture formatter for Prog and replace it with
a global String method. Clean up and regularize the output. Update
tests affected by the format; some tests are made correct now when
they were broken before (and known to be).
Also, related: Change the encoding of the (R1+R2) syntax on ppc64
to be equivalent to (R1)(R2*1), which means it needs no special
handling.
Delete the now unused STRINGSZ constant.
Change-Id: I7f6654d11f80065f3914a3f19353f2f12edfe310
Reviewed-on: https://go-review.googlesource.com/6931
Reviewed-by: Russ Cox <rsc@golang.org>
Make cmd/internal/obj/x86 support 32-bit mode and use
instead of cmd/internal/obj/i386. Delete cmd/internal/obj/i386.
Clean up encoding of PINSRQ, CMPSD to use explicit third arg
instead of jamming it into an unused slot of a different arg.
Also fix bug in old6a, which declared the wrong grammar.
The accepted (and encoded) arguments to CMPSD etc are mem,reg not reg,mem.
Code that did try to use mem,reg before would be rejected by liblink,
so only reg,reg ever worked, so existing code is not affected.
After this change, code can use mem,reg successfully.
The real bug here is that the encoding tables inverted the argument
order, making the comparisons all backward from what they say on the page.
It's too late to swap them, though: people have already written code that
expects the inverted comparisons (like in package math, and likely externally).
The best we can do is make the argument that should and can take a
memory operand accept it.
Bit-for-bit compatibility checked against tree without this CL.
Change-Id: Ife5685bc98c95001f64407f35066b34b4dae11c1
Reviewed-on: https://go-review.googlesource.com/6810
Reviewed-by: Rob Pike <r@golang.org>
This avoids repeated allocation and map lookups
when constructing the pcln tables.
For 6g compiling cmd/internal/gc/*.go this saves about 8% wall time.
Change-Id: I6a1a80e278ae2c2a44bd1537015ea7b4e7a4d6ca
Reviewed-on: https://go-review.googlesource.com/6793
Reviewed-by: Rob Pike <r@golang.org>
Aconv is the pretty-printer for instruction opcodes like AMOVQ.
There was one for each architecture.
Make the space of A names have a different region for each architecture,
much as we did for the registers, so a single global Aconv function can
do the work. Each architecture registers its region as a slice of names
at a given offset.
The global names like CALL and JMP are now defined only once.
The A values are used for indexing tables, so make it easy to do the
indexing by making the offset maskable.
Remove a bunch of now-duplicated architecture-specific code.
Change-Id: Ib15647b7145a1c089e21e36543691a19e146b60e
Reviewed-on: https://go-review.googlesource.com/6620
Reviewed-by: Russ Cox <rsc@golang.org>
Run-TryBot: Rob Pike <r@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
It is unused and should have been deleted when Rconv was made
a global function.
Change-Id: Id745dcee6f0769604cabde04887c6d0c94855405
Reviewed-on: https://go-review.googlesource.com/6521
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Have the implementations of each architecture declare the one-operand,
destination-writing instructions instead of splitting the information between
there and asm.
Change-Id: I44899435011a4a7a398ed03c0801e9f81cc8c905
Reviewed-on: https://go-review.googlesource.com/6490
Reviewed-by: Russ Cox <rsc@golang.org>
Replaced by Ctxt.ByteOrder, which uses the standard binary.ByteOrder type.
Change-Id: I06cec0674c153a9ad75ff937f7eb934891effd0b
Reviewed-on: https://go-review.googlesource.com/6450
Reviewed-by: Dave Cheney <dave@cheney.net>
Reviewed-by: Rob Pike <r@golang.org>
ARM operands for MOVM have lists of registers: [R1,R2,R5-R8].
Handle them cleanly.
It was TYPE_CONST with special handling, which meant operand printing
didn't work right and the special handling was ugly. Add a new TYPE_REGLIST
for this case and it all gets cleaner.
Change-Id: I4a64f70fb9765e63cb636619a7a8553611bfe970
Reviewed-on: https://go-review.googlesource.com/6300
Run-TryBot: Rob Pike <r@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Russ Cox <rsc@golang.org>
Clean up the obj API by making Rconv (register pretty printer) a top-level
function. This means that Dconv (operand pretty printer) doesn't need
an Rconv argument.
To do this, we make the register numbers, which are arbitrary inside an
operand (obj.Addr), disjoint sets for each architecture. Each architecture
registers (ha) a piece of the space and then the global Rconv knows which
architecture-specific printer to use.
Clean up all the code that uses Dconv.
Now register numbers are large, so a couple of fields in Addr need to go
from int8 to int16 because they sometimes hold register numbers. Clean
up their uses, which meant regenerating the yacc grammars for the
assemblers. There are changes in this CL triggered by earlier changes
to yacc, which had not been run in this directory.
There is still cleanup to do in Addr, but we're getting closer to that being
easy to do.
Change-Id: I9290ebee013b62f7d24e886743ea5a6b232990ab
Reviewed-on: https://go-review.googlesource.com/6220
Reviewed-by: Russ Cox <rsc@golang.org>
Each architecture had its own Dconv (operand printer) but the syntax is
close to uniform and the code overlap was considerable. Consolidate these
into a single top-level function. A similar but smaller unification is done
for Mconv ("Name" formatter) as well.
The signature is changed. The flag was unused so drop it. Add a
function argument, Rconv, that must be supplied by the caller.
TODO: A future change will unify Rconv as well and this argument
will go away.
Some formats changed, because of the automatic consistency
created by unification. For instance, 0(R1) always prints as (R1)
now, and foo+0(SB) is just foo(SB). Before, some made these
simplifications and some didn't; now they all do.
Update the asm tests that depend on the format.
Change-Id: I6e3310bc19814c0c784ff0b960a154521acd9532
Reviewed-on: https://go-review.googlesource.com/5920
Reviewed-by: Russ Cox <rsc@golang.org>
Reconvert using rsc.io/c2go rev 27b3f59.
Changes to converter:
- fatal does not return, so no fallthrough after fatal in switch
- many more function results and variables identified as bool
- simplification of negated boolean expressions
Change-Id: I3bc67da5e46cb7ee613e230cf7e9533036cc870b
Reviewed-on: https://go-review.googlesource.com/5171
Reviewed-by: Josh Bleecher Snyder <josharian@gmail.com>
First draft of converted Go compiler, using rsc.io/c2go rev 83d795a.
Change-Id: I29f4c7010de07d2ff1947bbca9865879d83c32c3
Reviewed-on: https://go-review.googlesource.com/4851
Reviewed-by: Rob Pike <r@golang.org>
cmd/internal/obj reconverted using rsc.io/c2go rev 2a95256.
- Brings in new, more regular Prog, Addr definitions
- Add Prog* argument to oclass in liblink/asm[68].c, for c2go conversion.
- Update objwriter for change in TEXT size encoding.
- Merge 5a, 6a, 8a, 9a changes into new5a, new6a, new8a, new9a (by hand).
- Add +build ignore to cmd/asm/internal/{addr,arch,asm}, cmd/asm.
They need to be updated for the changes.
- Reenable verifyAsm in cmd/go.
- Reenable GOOBJ=2 mode by default in liblink.
All architectures build successfully again.
Change-Id: I2c845c5d365aa484b570476898171bee657b626d
Reviewed-on: https://go-review.googlesource.com/3963
Reviewed-by: Rob Pike <r@golang.org>
cmd/internal/obj reconverted using rsc.io/c2go rev 40275b8.
All Prog*s need Ctxt field set so that the printer can tell
which architecture the Prog belongs to.
Use ctxt.NewProg consistently for this.
Change-Id: Ic981b3d68f24931ffae74a772e83a3dc2fdf518a
Reviewed-on: https://go-review.googlesource.com/3152
Reviewed-by: Rob Pike <r@golang.org>
For new assembler, reconvert using rsc.io/c2go rev f9db76e.
- Removes trailing _ from Go keywords that are exported.
- Export regstr as Register, anames[5689] as Anames.
Also update clients.
Change-Id: I41c8fd2d14490236f548b4aa0ed0b9bd7571d2d7
Reviewed-on: https://go-review.googlesource.com/3151
Reviewed-by: Rob Pike <r@golang.org>
This CL adds the real cmd/internal/obj packages.
Collectively they correspond to the liblink library.
The conversion was done using rsc.io/c2go's run script
at rsc.io/c2go repo version 706fac7.
This is not the final conversion, just the first working draft.
There will be more updates, but this works well enough
to use with go tool objwriter and pass all.bash.
Change-Id: I9359e835425f995a392bb2fcdbebf29511477bed
Reviewed-on: https://go-review.googlesource.com/3046
Reviewed-by: Ian Lance Taylor <iant@golang.org>