Just happened to notice that these names (funcAlign and friends) are
never referenced outside their package, so no need to export them.
Change-Id: I4bbdaa4b0ef330c3c3ef50a2ca39593977a83545
Reviewed-on: https://go-review.googlesource.com/31496
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: David Crawshaw <crawshaw@golang.org>
Replace the various calls to Fprintf(ctxt.Bso, ...) with a helper,
ctxt.Logf. This also addresses the various inconsistent flushing of
ctxt.Bso.
Because we have two Link structures, add Link.Logf in both places.
Change-Id: I23093f9b9b3bf33089a0ffd7f815f92dcd1a1fa1
Reviewed-on: https://go-review.googlesource.com/27730
Reviewed-by: Matthew Dempsky <mdempsky@google.com>
Now that assembler opcodes have their own type, they can have a true
stringer, rather than explicit calls to Aconv, which makes for nicer
format strings.
Change-Id: Ic77f5f8ac38b4e519dcaa08c93e7b732226f7bfe
Reviewed-on: https://go-review.googlesource.com/25045
Run-TryBot: Michael Pratt <mpratt@google.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Reviewed-by: Josh Bleecher Snyder <josharian@gmail.com>
a new relocation R_ADDRMIPSTLS is added, which resolves to 16-bit offset
of a TLS address on mips64x.
Change-Id: Ic60d0e1ba49ff1c433cead242f5884677ab227a5
Reviewed-on: https://go-review.googlesource.com/19804
Reviewed-by: Minux Ma <minux@golang.org>
SB register (R28) is introduced for access external addresses with shorter
instruction sequences. It is loaded at entry points. External data within
2G of SB can be accessed this way.
cmd/internal/obj: relocaltion R_ADDRMIPS is split into two relocations
R_ADDRMIPS and R_ADDRMIPSU, handling the low 16 bits and the "upper" 16
bits of external addresses, respectively, since the instructios may not
be adjacent. It might be better if relocation Variant could be used.
cmd/link/internal/mips64: support new relocations.
cmd/compile/internal/mips64: reserve SB register.
runtime: initialize SB register at entry points.
Change-Id: I5f34868f88c5a9698c042a8a1f12f76806c187b9
Reviewed-on: https://go-review.googlesource.com/19802
Reviewed-by: Minux Ma <minux@golang.org>
Generated with honnef.co/go/unused
There is a large amount of unused code in cmd/internal/obj/s390x but
that can wait til the s390x port is merged.
There is some unused code in
cmd/internal/unvendor/golang.org/x/arch/arm/armasm but that should be
addressed upstream and a new revision imported.
Change-Id: I252c0f9ea8c5bb1a0b530a374ef13a0a20ea56aa
Reviewed-on: https://go-review.googlesource.com/21782
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Run-TryBot: Dave Cheney <dave@cheney.net>
Currently, package obj reserves a range of 1<<12 opcodes for each
target architecture. E.g., mips64 has [6<<12, 7<<12).
However, because mips.ABEQ and mips.ALAST are both within that range,
the expression mips.ABEQ+mips.ALAST in turn falls (far) outside that
range around 12<<12, meaning it could theoretically collide with
another arch's opcodes.
More practically, it's a problem because 12<<12 overflows an int16,
which hampers fixing #14692. (We could also just switch to uint16 to
avoid the overflow, but that still leaves the first problem.)
As a workaround, use Michael Hudson-Doyle's solution from
https://golang.org/cl/20182 and use negative values for these variant
instructions.
Passes toolstash -cmp for GOARCH=arm and GOARCH=mips64.
Updates #14692.
Change-Id: Iad797d10652360109fa4db19d4d1edb6529fc2c0
Reviewed-on: https://go-review.googlesource.com/20345
Run-TryBot: Matthew Dempsky <mdempsky@google.com>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
When using GOEXPERIMENT=fieldtrack, we can see AUSEFIELD instructions.
We generally want to ignore them.
No tests because as far as I can tell there are no tests for
GOEXPERIMENT=fieldtrack.
Change-Id: Iee26f25592158e5db691a36cf8d77fc54d051314
Reviewed-on: https://go-review.googlesource.com/17610
Reviewed-by: David Symonds <dsymonds@golang.org>
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
MIPS64 has 32 general purpose 64-bit integer registers (R0-R31), 32
64-bit floating point registers (F0-F31). Instructions are fixed-width,
and are 32-bit wide. Instructions are all in standard 1-, 2-, 3-operand
forms.
MIPS64-specific relocations are added. For this reason, test data of
cmd/newlink are regenerated.
No other changes are made to portable structures.
Branch delay slots are current filled with NOP instructions. The function
for instruction scheduling (try to fill the delay slot with a useful
instruction) is implemented but disabled for now.
Change-Id: Ic364999c7a33245260c1381fc26a2fa8972d38b3
Reviewed-on: https://go-review.googlesource.com/14442
Reviewed-by: Minux Ma <minux@golang.org>
It's particularly nice to get rid of the android special cases in the linker.
Change-Id: I516363af7ce8a6b2f196fe49cb8887ac787a6dad
Reviewed-on: https://go-review.googlesource.com/14197
Run-TryBot: Michael Hudson-Doyle <michael.hudson@canonical.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Just a mechanical copy with filename renames, no code changes.
This is to reduce code difference when adding the mips64 port.
Change-Id: Id06e975f414a7b09f4827167b30813b228a3bfae
Reviewed-on: https://go-review.googlesource.com/14323
Reviewed-by: Ian Lance Taylor <iant@golang.org>