Currently, zeroing generates an ssa.OpZero, which never has write
barriers, even if the assignment is an OASWB. The hybrid barrier
requires write barriers on zeroing, so change OASWB to generate an
ssa.OpZeroWB when assigning the zero value, which turns into a
typedmemclr.
Updates #17503.
Change-Id: Ib37ac5e39f578447dbd6b36a6a54117d5624784d
Reviewed-on: https://go-review.googlesource.com/31451
Reviewed-by: Cherry Zhang <cherryyz@google.com>
When the compiler insert write barriers, the frontend makes
conservative decisions at an early stage. This may have false
positives which result in write barriers for stack writes.
A new phase, writebarrier, is added to the SSA backend, to delay
the decision and eliminate false positives. The frontend still
makes conservative decisions. When building SSA, instead of
emitting runtime calls directly, it emits WB ops (StoreWB,
MoveWB, etc.), which will be expanded to branches and runtime
calls in writebarrier phase. Writes to static locations on stack
are detected and write barriers are removed.
All write barriers of stack writes found by the script from
issue #17330 are eliminated (except two false positives).
Fixes#17330.
Change-Id: I9bd66333da9d0ceb64dcaa3c6f33502798d1a0f8
Reviewed-on: https://go-review.googlesource.com/31131
Reviewed-by: Austin Clements <austin@google.com>
Reviewed-by: David Chase <drchase@google.com>
Reviewed-by: Keith Randall <khr@golang.org>