2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								<?xml version="1.0" encoding="UTF-8" ?>  
						 
					
						
							
								
									
										
										
										
											2023-07-06 10:08:05 +02:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								<class  name= "VisualShaderNodeIntParameter"  inherits= "VisualShaderNodeParameter"  xmlns:xsi= "http://www.w3.org/2001/XMLSchema-instance"  xsi:noNamespaceSchemaLocation= "../class.xsd" >  
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
									<brief_description > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
										A visual shader node for shader parameter (uniform) of type [int].
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
									</brief_description> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									<description > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
										A [VisualShaderNodeParameter] of type [int]. Offers additional customization for range of accepted values.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
									</description> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									<tutorials > 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									</tutorials> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									<members > 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<member  name= "default_value"  type= "int"  setter= "set_default_value"  getter= "get_default_value"  default= "0" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											Default value of this parameter, which will be used if not set externally. [member default_value_enabled] must be enabled; defaults to [code]0[/code] otherwise.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</member> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<member  name= "default_value_enabled"  type= "bool"  setter= "set_default_value_enabled"  getter= "is_default_value_enabled"  default= "false" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											If [code]true[/code], the node will have a custom default value.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</member> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<member  name= "hint"  type= "int"  setter= "set_hint"  getter= "get_hint"  enum= "VisualShaderNodeIntParameter.Hint"  default= "0" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											Range hint of this node. Use it to customize valid parameter range.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</member> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<member  name= "max"  type= "int"  setter= "set_max"  getter= "get_max"  default= "100" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											The maximum value this parameter can take. [member hint] must be either [constant HINT_RANGE] or [constant HINT_RANGE_STEP] for this to take effect.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</member> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<member  name= "min"  type= "int"  setter= "set_min"  getter= "get_min"  default= "0" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											The minimum value this parameter can take. [member hint] must be either [constant HINT_RANGE] or [constant HINT_RANGE_STEP] for this to take effect.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</member> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<member  name= "step"  type= "int"  setter= "set_step"  getter= "get_step"  default= "1" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											The step between parameter's values. Forces the parameter to be a multiple of the given value. [member hint] must be [constant HINT_RANGE_STEP] for this to take effect.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</member> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									</members> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									<constants > 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<constant  name= "HINT_NONE"  value= "0"  enum= "Hint" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											The parameter will not constrain its value.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</constant> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<constant  name= "HINT_RANGE"  value= "1"  enum= "Hint" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											The parameter's value must be within the specified [member min]/[member max] range.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</constant> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<constant  name= "HINT_RANGE_STEP"  value= "2"  enum= "Hint" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											The parameter's value must be within the specified range, with the given [member step] between values.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</constant> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
										<constant  name= "HINT_MAX"  value= "3"  enum= "Hint" > 
							 
						 
					
						
							
								
									
										
										
										
											2022-12-07 15:59:34 +01:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
											Represents the size of the [enum Hint] enum.
							 
						 
					
						
							
								
									
										
										
										
											2022-08-27 12:22:43 +03:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
										</constant> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									</constants> 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								</class>